    A real-time phasor data only state estimator and its application to real power systems

    Author
    Fernandes, Emily
    View/Open
    175930_Fernandes_rpi_0185N_10587.pdf (2.314Mb)
    Other Contributors
    Chow, J. H. (Joe H.), 1951-; Parsa, Leila; Wang, Meng;
    Date Issued
    2015-05
    Subject
    Electrical engineering
    Degree
    MS;
    Terms of Use
    This electronic version is a licensed copy owned by Rensselaer Polytechnic Institute, Troy, NY. Copyright of original work retained by author.;
    Metadata
    Show full item record
    URI
    https://hdl.handle.net/20.500.13015/1453
    Abstract
    Previous work, completed by Dr. Luigi Vanfretti, developed a phasor-only state estimator which used correction factors to account for the inherent inaccuracies found in measurements added from the equipment in the field. This proposed phasor state estimator not only estimates the voltage magnitudes and angles, but also variables that account for measurement error such as angle biases and current scaling factors. Dr. Scott Ghiocel then applied this state estimator to a small subset of the Central New York system in order to study the use of the PSE to a larger system. In this thesis we will study the application of the phasor-only state estimator to a wide-scale power system, enumerate the changes required to adapt the phasor-only state estimator to handle a real system and describe the steps taken to advance the phasor-only state estimator to a near real time application.; With the growing concern about reliability in the electrical system, it is important for those monitoring the grid to receive a clear and holistic snap shot of the high voltage portions of the grid in real time. It is possible to achieve real time situational awareness using phasor data. There are several issues that must be addressed when using phasor data. PMU measurements have opportunities for inaccuracies which are usually introduced by human error. Another issue is that unlike the current standard measurements, Phasor Measurement Units do not cover the entire electrical system. Using a phasor-only state estimator, it is possible to both enhance data quality by removing angle error and expand the observable area of the grid.;
    Description
    May 2015; School of Engineering
    Department
    Dept. of Electrical, Computer, and Systems Engineering;
    Publisher
    Rensselaer Polytechnic Institute, Troy, NY
    Relationships
    Rensselaer Theses and Dissertations Online Collection;
    Access
    Restricted to current Rensselaer faculty, staff and students. Access inquiries may be directed to the Rensselaer Libraries.;
    Collections
    • RPI Theses Online (Complete)

    Browse

    All of DSpace@RPICommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    Login

    DSpace software copyright © 2002-2022  DuraSpace
    Contact Us | Send Feedback
    DSpace Express is a service operated by 
    Atmire NV