Development of front-end electronics for large area solid-state neutron detector arrays
dc.rights.license | CC BY-NC-ND. Users may download and share copies with attribution in accordance with a Creative Commons Attribution-Noncommercial-No Derivative Works 3.0 License. No commercial use or derivatives are permitted without the explicit approval of the author. | |
dc.contributor | Hella, Mona Mostafa | |
dc.contributor | Saulnier, Gary J. | |
dc.contributor | Bhat, Ishwara B. | |
dc.contributor.author | English, Erik | |
dc.date.accessioned | 2021-11-03T08:31:41Z | |
dc.date.available | 2021-11-03T08:31:41Z | |
dc.date.created | 2016-02-09T07:49:34Z | |
dc.date.issued | 2015-12 | |
dc.identifier.uri | https://hdl.handle.net/20.500.13015/1581 | |
dc.description | December 2015 | |
dc.description | School of Engineering | |
dc.description.abstract | Solid-state neutron detectors represent a potential replacement technology for Helium-3 gas filled tubes used for detection of special nuclear materials. When scaling these detectors to very large areas the design of the associated electronics becomes critical to overall detection efficiency. This thesis explores the implementation of low noise readout electronics optimized for large area semiconductor neutron detector arrays. The readout system consists of a charge sensitive preamplifier, pulse shaper, and fast threshold crossing discriminator. Three different designs have been implemented, two of which are built using discrete parts on a printed circuit board while the third has been fabricated using the IBM 0.13um CMOS process. Additionally, a novel preamplifier topology, utilizing a capacitance canceling input stage, is presented. Experimental results show that the utilization of a capacitance canceling stage has the capability to lower preamplifier noise by up to 15%. Finally, the CMOS implementation possesses the highest reported performance, in terms of noise and power, for high capacitance detectors to date. | |
dc.language.iso | ENG | |
dc.publisher | Rensselaer Polytechnic Institute, Troy, NY | |
dc.relation.ispartof | Rensselaer Theses and Dissertations Online Collection | |
dc.rights | Attribution-NonCommercial-NoDerivs 3.0 United States | * |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/3.0/us/ | * |
dc.subject | Electrical engineering | |
dc.title | Development of front-end electronics for large area solid-state neutron detector arrays | |
dc.type | Electronic thesis | |
dc.type | Thesis | |
dc.digitool.pid | 176904 | |
dc.digitool.pid | 176905 | |
dc.digitool.pid | 176906 | |
dc.rights.holder | This electronic version is a licensed copy owned by Rensselaer Polytechnic Institute, Troy, NY. Copyright of original work retained by author. | |
dc.description.degree | MS | |
dc.relation.department | Dept. of Electrical, Computer, and Systems Engineering |
Files in this item
This item appears in the following Collection(s)
-
RPI Theses Online (Complete)
Rensselaer theses from 2006; many restricted to current RPI Students, Faculty and Staff -
RPI Theses Open Access
Rensselaer Theses and Dissertations with Creative Commons Licenses
Except where otherwise noted, this item's license is described as CC BY-NC-ND. Users may download and share copies with attribution in accordance with a Creative Commons Attribution-Noncommercial-No Derivative Works 3.0 License. No commercial use or derivatives are permitted without the explicit approval of the author.