dc.rights.license | Restricted to current Rensselaer faculty, staff and students. Access inquiries may be directed to the Rensselaer Libraries. | |
dc.contributor | Danon, Yaron | |
dc.contributor | Liu, Li (Emily) | |
dc.contributor | Ji, Wei | |
dc.contributor | Slaybaugh, Rachel | |
dc.contributor.author | Thompson, Nicholas | |
dc.date.accessioned | 2021-11-03T08:53:38Z | |
dc.date.available | 2021-11-03T08:53:38Z | |
dc.date.created | 2017-11-10T12:49:25Z | |
dc.date.issued | 2017-08 | |
dc.identifier.uri | https://hdl.handle.net/20.500.13015/2060 | |
dc.description | August 2017 | |
dc.description | School of Engineering | |
dc.description.abstract | Data was collected as a function of time after neutron pulse, or slowing-down time, which is correlated to average neutron energy. An analog and a digital data acquisition system collected data simultaneously, allowing for collection of pulse shape information as well as timing. Collection of digital data allowed for pulse shape analysis after the experiment. This data was then analyzed and compared to Monte Carlo simulations to validate the accuracy of neutron capture cross section libraries. These measurements represent the first time that neutron capture cross sections have been measured using an LSDS in the United States, and the first time tools such as coincidence measurements and pulse height weighting have been applied to measurements of neutron capture cross sections using an LSDS. Significant differences between measurement results and simulation results were found in multiple materials, and some errors in nuclear data libraries have already been identified due to these measurements. | |
dc.description.abstract | Accurate nuclear data is essential for the modeling, design, and operation of nuclear systems. In this work, the Rensselaer Polytechnic Institute (RPI) Lead Slowing-Down Spectrometer (LSDS) at the Gaerttner Linear Accelerator Center (LINAC) was used to measure neutron capture cross sections and validate capture cross sections in cross section libraries. The RPI LINAC was used to create a fast burst of neutrons in the center of the LSDS, a large cube of high purity lead. A sample and YAP:Ce scintillator were placed in the LSDS, and as neutrons lost energy through scattering interactions with the lead, the scintillator detected capture gammas resulting from neutron capture events in the sample. Samples of silver, gold, cobalt, iron, indium, molybdenum, niobium, nickel, tin, tantalum, and zirconium were measured. | |
dc.language.iso | ENG | |
dc.publisher | Rensselaer Polytechnic Institute, Troy, NY | |
dc.relation.ispartof | Rensselaer Theses and Dissertations Online Collection | |
dc.subject | Nuclear engineering and science | |
dc.title | Measuring and validating neutron capture cross sections using a lead slowing-down spectrometer | |
dc.type | Electronic thesis | |
dc.type | Thesis | |
dc.digitool.pid | 178590 | |
dc.digitool.pid | 178591 | |
dc.digitool.pid | 178592 | |
dc.rights.holder | This electronic version is a licensed copy owned by Rensselaer Polytechnic Institute, Troy, NY. Copyright of original work retained by author. | |
dc.description.degree | PhD | |
dc.relation.department | Dept. of Mechanical, Aerospace, and Nuclear Engineering | |