    Quantitative capillary electrophoresis determination of oversulfated chondroitin sulfate as a contaminant in heparin preparations

    Author
    Volpi, Nicola; Maccari, Francesca; Linhardt, Robert J.
    ORCID
    https://orcid.org/0000-0003-2219-5833
    Thumbnail
    View/Open
    QUANTITATIVE CAPILLARY ELECTROPHORESIS DETERMINATION OF.pdf (2.830Mb)
    Other Contributors
    Date Issued
    2009-05-01
    Subject
    Biology; Chemistry and chemical biology; Chemical and biological engineering; Biomedical engineering
    Degree
    Terms of Use
    In Copyright : this Item is protected by copyright and/or related rights. You are free to use this Item in any way that is permitted by the copyright and related rights legislation that applies to your use. For other uses you need to obtain permission from the rights-holder(s). https://rightsstatements.org/page/InC/1.0/;
    Full Citation
    Quantitative capillary electrophoresis determination of oversulfated chondroitin sulfate as a contaminant in heparin preparations, N. Volpi, F. Maccari, R. J. Linhardt, Analytical Biochemistry, 388, 140-145, 2009.
    Metadata
    Show full item record
    URI
    https://hdl.handle.net/20.500.13015/5220; https://doi.org/10.1016/j.ab.2009.02.012
    Abstract
    A simple, accurate, and robust quantitative capillary electrophoresis (CE) method for the determination of oversulfated chondroitin sulfate (OSCS) as a contaminant in heparin (Hep) preparations is described. After degradation of the polysaccharides by acidic hydrolysis, the hexosamines produced (i.e., GlcN from Hep and GalN from OSCS) were derivatized with anthranilic acid (AA) and separated by means of CE in approximately 10 min with high sensitivity detection at 214 nm (limit of detection [LOD] of approximately 200 pg). Furthermore, AA-derivatized GlcN and GalN showed quite similar molar absorptivity, allowing direct and simple quantification of OSCS in Hep samples. Moreover, a preliminary step of specific enzymatic treatment by using chondroitin ABC lyase may be applied for the specific elimination of interference in the analysis due to the possible presence in Hep samples of natural chondroitin sulfate and dermatan sulfate impurities, making this analytical approach highly specific for OSCS contamination given that chondroitin ABC lyase is unable to act on this semisynthetic polymer. The CE method was validated for specificity, linearity, accuracy, precision, LOD, and limit of quantification (LOQ). Due to the very high sensitivity of CE, as little as 1% OSCS contaminant in Hep sample could be detected and quantified. Finally, a contaminated raw Hep sample was found to contain 38.9% OSCS, whereas a formulated contaminated Hep was calculated to have 39.7% OSCS.;
    Description
    Analytical Biochemistry, 388, 140-145; Note : if this item contains full text it may be a preprint, author manuscript, or a Gold OA copy that permits redistribution with a license such as CC BY. The final version is available through the publisher’s platform.
    Department
    The Linhardt Research Labs.; The Shirley Ann Jackson, Ph.D. Center for Biotechnology and Interdisciplinary Studies (CBIS);
    Publisher
    Elsevier
    Relationships
    The Linhardt Research Labs Online Collection; Rensselaer Polytechnic Institute, Troy, NY; Analytical Biochemistry; https://harc.rpi.edu/;
    Access
    A full text version is available in DSpace@RPI;
    Collections
    • Linhardt Research Labs Papers

    Browse

    All of DSpace@RPICommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    Login

    DSpace software copyright © 2002-2022  DuraSpace
    Contact Us | Send Feedback
    DSpace Express is a service operated by 
    Atmire NV