• Login
    View Item 
    •   DSpace@RPI Home
    • The Linhardt Research Labs
    • Linhardt Research Labs Papers
    • View Item
    •   DSpace@RPI Home
    • The Linhardt Research Labs
    • Linhardt Research Labs Papers
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Analysis of pharmaceutical heparins and potential contaminants using 1H-NMR and PAGE

    Author
    Zhang, Zhenqing; Li, Boyangzi; Suwan, Jiraporn; Zhang, Fuming; Wang, Zhenyu; Liu, Haiying; Mulloy, Barbara; Linhardt, Robert J.
    ORCID
    https://orcid.org/0000-0003-2219-5833
    Thumbnail
    Other Contributors
    Date Issued
    2009-01-01
    Subject
    Biology; Chemistry and chemical biology; Chemical and biological engineering; Biomedical engineering
    Degree
    Terms of Use
    In Copyright : this Item is protected by copyright and/or related rights. You are free to use this Item in any way that is permitted by the copyright and related rights legislation that applies to your use. For other uses you need to obtain permission from the rights-holder(s). https://rightsstatements.org/page/InC/1.0/;
    Full Citation
    Analysis of pharmaceutical heparins and potential contaminants using 1H-NMR and PAGE, Z. Zhang, B. Li, J. Suwan, F. Zhang, Z. Wang, H. Liu, B. Mulloy, R. J. Linhardt, Journal of Pharmaceutical Science, 98, 4017-4026, 2009.
    Metadata
    Show full item record
    URI
    https://doi.org/10.1002/jps.21729; https://hdl.handle.net/20.500.13015/5748
    Abstract
    In 2008, heparin (active pharmaceutical ingredient, API) lots were associated with anaphylactoid-type reactions. Oversulfated chondroitin sulfate (OSCS), a semi-synthetic glycosaminoglycan (GAG), was identified as a contaminant and dermatan sulfate (DS) as an impurity. While DS has no known toxicity, OSCS was toxic leading to patient deaths. Heparins, prepared before these adverse reactions, needed to be screened for impurities and contaminants. Heparins were analyzed using high-field (1)H-NMR spectroscopy. Heparinoids were mixed with a pure heparin and analyzed by (1)H-NMR to assess the utility of (1)H-NMR for screening heparin adulterants. Sensitivity of heparinoids to deaminative cleavage, a method widely used to depolymerize heparin, was evaluated with polyacrylamide gel electrophoresis to detect impurities and contaminants, giving limits of detection (LOD) ranging from 0.1% to 5%. Most pharmaceutical heparins prepared between 1941 and 2008 showed no impurities or contaminants. Some contained DS, CS, and sodium acetate impurities. Heparin prepared in 2008 contained OSCS contaminant. Heparin adulterated with heparinoids showed additional peaks in their high-field (1)H-NMR spectra, clearly supporting NMR for monitoring of heparin API with an LOD of 0.5-10%. Most of these heparinoids were stable to nitrous acid treatment suggesting its utility for evaluating impurities and contaminants in heparin API.;
    Description
    Journal of Pharmaceutical Science, 98, 4017-4026; Note : if this item contains full text it may be a preprint, author manuscript, or a Gold OA copy that permits redistribution with a license such as CC BY. The final version is available through the publisher’s platform.
    Department
    The Linhardt Research Labs.; The Shirley Ann Jackson, Ph.D. Center for Biotechnology and Interdisciplinary Studies (CBIS);
    Relationships
    The Linhardt Research Labs Online Collection; Rensselaer Polytechnic Institute, Troy, NY; Journal of Pharmaceutical Sciences; https://harc.rpi.edu/;
    Access
    https://login.libproxy.rpi.edu/login?url=https://doi.org/10.1002/jps.21729;
    Collections
    • Linhardt Research Labs Papers

    Browse

    All of DSpace@RPICommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    Login

    DSpace software copyright © 2002-2022  DuraSpace
    Contact Us | Send Feedback
    DSpace Express is a service operated by 
    Atmire NV