dc.contributor.author | Klein, Michael D. | |
dc.contributor.author | Drongowski, Robert A. | |
dc.contributor.author | Linhardt, Robert J. | |
dc.contributor.author | Langer, Robert S. | |
dc.date | 1982 | |
dc.date.accessioned | 2022-06-27T17:16:06Z | |
dc.date.available | 2022-06-27T17:16:06Z | |
dc.date.issued | 1982-07-15 | |
dc.identifier.citation | A Colorimetric Assay for Chemical Heparin in Plasma, M. Klein, R.A. Drongowski, R.J. Linhardt, R. Langer, Analytical Biochemistry, 124, 59-64 (1982). | |
dc.identifier.issn | 10960309 | |
dc.identifier.issn | 32697 | |
dc.identifier.uri | https://doi.org/10.1016/0003-2697(82)90219-6 | |
dc.identifier.uri | https://hdl.handle.net/20.500.13015/6037 | |
dc.description | Analytical Biochemistry, 124, 59-64 | |
dc.description | Note : if this item contains full text it may be a preprint, author manuscript, or a Gold OA copy that permits redistribution with a license such as CC BY. The final version is available through the publisher’s platform. | |
dc.description.abstract | A simple, rapid colorimetric assay for plasma heparin is presented. The assay employs the metachromasia of azure A when heparin is added. It is useful for 0 to 10 units/ml and does not depend on heparin's anticoagulant activity. Heparin concentrations determined with this assay are not exactly the same as those determined with coagulation assays. This is probably because azure A determines chemical heparin, not anticoagulant active heparin. | |
dc.description.sponsorship | National Institutes of Health | |
dc.description.uri | https://login.libproxy.rpi.edu/login?url=https://doi.org/10.1016/0003-2697(82)90219-6 | |
dc.language | en_US | |
dc.language.iso | ENG | |
dc.relation.ispartof | The Linhardt Research Labs Online Collection | |
dc.relation.ispartof | Rensselaer Polytechnic Institute, Troy, NY | |
dc.relation.ispartof | Analytical Biochemistry | |
dc.relation.uri | https://harc.rpi.edu/ | |
dc.subject | Biology | |
dc.subject | Chemistry and chemical biology | |
dc.subject | Chemical and biological engineering | |
dc.subject | Biomedical engineering | |
dc.title | A Colorimetric Assay for Chemical Heparin in Plasma | |
dc.type | Article | |
dcterms.accessRights | https://login.libproxy.rpi.edu/login?url=https://doi.org/10.1016/0003-2697(82)90219-6 | |
dcterms.isPartOf | Journal | |
dcterms.isVersionOf | https://doi.org/10.1016/0003-2697(82)90219-6 | |
dc.rights.holder | In Copyright : this Item is protected by copyright and/or related rights. You are free to use this Item in any way that is permitted by the copyright and related rights legislation that applies to your use. For other uses you need to obtain permission from the rights-holder(s). https://rightsstatements.org/page/InC/1.0/ | |
dc.creator.identifier | https://orcid.org/0000-0003-2219-5833 | |
dc.relation.department | The Linhardt Research Labs. | |
dc.relation.department | The Shirley Ann Jackson, Ph.D. Center for Biotechnology and Interdisciplinary Studies (CBIS) | |
rpi.description.pages | 59-64 | |
rpi.description.volume | 124 | |