Verification of three-microphone impedance tube method for measurement of transmission loss in aerogels

Authors
Connick, Robert J.
ORCID
Loading...
Thumbnail Image
Other Contributors
Xiang, Ning
Braasch, Jonas
Markov, Ivan
Issue Date
2013-08
Keywords
Architectural sciences
Degree
MS
Terms of Use
This electronic version is a licensed copy owned by Rensselaer Polytechnic Institute, Troy, NY. Copyright of original work retained by author.
Full Citation
Abstract
Accurate measurement of normal incident transmission loss is essential for the acoustic characterization of building materials. In this research, a method of measuring normal incidence sound transmission loss proposed by Salissou et al. as a complement to standard E2611-09 of the American Society for Testing and Materials [Standard Test Method for Measurement of Normal Incidence Sound Transmission of Acoustical Materials Based on the Transfer Matrix Method (American Society for Testing and Materials, New York, 2009)] is verified. Two sam- ples from the original literature are used to verify the method as well as a FiltrosĀ® sample. Following the verification, several nano-material Aerogel samples are measured.
Description
August 2013
School of Architecture
Department
School of Architecture
Publisher
Rensselaer Polytechnic Institute, Troy, NY
Relationships
Rensselaer Theses and Dissertations Online Collection
Access