Demonstration of a mid-infrared carbon monoxide sensor
Loading...
Authors
Herrick-Kaiser, Nicholas Fitzgerald
Issue Date
2008-12
Type
Electronic thesis
Thesis
Thesis
Language
ENG
Keywords
Aeronautical engineering
Alternative Title
Abstract
Initial stages in the development of a carbon monoxide diagnostic are completed. This diagnostic is unique in that it utilizes mid-infrared radiation generated by a quantum cascade laser to perform absorption spectroscopy. Past absorption spectroscopy systems have utilized the near-infrared; the mid-infrared region contains significantly stronger absorption features than the near-infrared, these stronger features can be harnessed to develop a diagnostic which is far more sensitive. The strong sensitivity of mid-infrared spectroscopy and small size of quantum cascade lasers enables the goal of a small, nonintrusive, highly sensitive diagnostic which can be used for process monitoring in various combustion and energy systems. A brief review of past work with quantum cascade lasers and basic absorption spectroscopy fundamentals are presented. Development of the diagnostic system is described in detail, including the principles behind quantum cascade lasers. Laser functionality is validated and initial qualitative measurements are made; the R(11) carbon monoxide absorbance line is observed and identified. Significant future work is required for accurate qualitative measurements on combustion and energy systems; suggestions for future work are given.
Description
May 2008
School of Engineering
School of Engineering
Full Citation
Publisher